对电流法、峰值功率法、均值功率法进行了总结,得出平衡块调整量的计算公式。均值法节电效果最明显,确定了均值功率平衡度的标准区间为75~120%。通过调整,ZC区块单井日节约耗电达17%,应用效果显著,年节约电费10余万元。
Summarize current balance method,peak power methods,and mean power methods. to obtain the calculation formula of the adjustment amount of the balance block. Among them,the mean power method is most obvious,and the standard interval of the mean power balance is determined to be 75~120%. Through the adjustment of balance,the single-mean power method of the single well is 17% in ZC oilfield,the application effect is remarkable,and the annual annual electricity bill is more than 10,000 yuan.
作者
房涛
陆斌
丁婷
李守仁
刘成
Fang Tao;Lu Bin;Ding Ting;Li Shou ren;Liu Cheng(Oil Production Plant of East China Branch Company,SINOPEC,Taizhou Jiangsu 225300)
出处
《石化技术》
CAS
2022年第7期108-110,共3页
Petrochemical Industry Technology
关键词
游梁式抽油机
均值功率法
调平衡
Beam pumping wells
Mean power methods
Balance adjustment