期刊文献+

半直驱永磁风力发电机温度场仿真 被引量:1

Temperature field simulation of semi direct drive permanent magnet wind turbine
下载PDF
导出
摘要 本文以3 MW半直驱永磁风力发电机为例进行温度场计算分析,利用有限元分析方法分别对3 MW半直驱永磁风力发电机额定工况及试验工况的温度场进行计算。计算结果与试验实测结果一致,永磁发电机温升满足考核要求。同时计算分析了冷却水流量及冷却管排布位置对温升的影响,并提出后续改进建议。 Taking 3MW half-direct drive permanent magnet wind turbine as an example,this paper calculates and analyzes the temperature field of 3MW half-direct drive permanent magnet wind turbine under rated condition and test condition by using the finite element analysis method.The calculated results are consistent with the test results,and the temperature rise of half-direct drive permanent magnet wind turbine meets the assessed requirements.At the same time,the influence of cooling water flow and cooling pipe layout on motor temperature rise is calculated and analyzed,and the follow-up improvement suggestions are put forward.
作者 曾湘黔 柳印 刘勇辉 程秀杰 Zeng Xiangqian;Liu Yin;Liu Yonghui;Cheng Xiujie(Ocean wind power technology and detection state key laboratory(XEMC)XiangTan,411101 HuNan,China;National energy wind power R&D(test)center,XiangTan,411101 HuNan,China)
出处 《船电技术》 2022年第9期50-55,共6页 Marine Electric & Electronic Engineering
关键词 半直驱永磁风力发电机 温度场 温升 冷却 half-direct drive permanent magnet wind turbine temperature field temperature rise cooling
  • 相关文献

参考文献3

二级参考文献14

共引文献86

同被引文献15

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部