摘要 盐酸多巴胺常被作为治疗心梗、脑梗及癫痫的特效西药,生物体内该物质分析检测技术备受关注。通过在碱性介质中盐酸多巴胺强烈抑制过氧化氢-鲁米诺和双功能化石墨烯(GO-ABEI-Hemin)体系的化学发光,建立了盐酸多巴胺静态注射化学发光分析检测法。考察了GO-ABEI-Hemin双功能发光材料用量、反应介质pH值和过氧化氢用量对该化学发光法测定多巴胺的影响。本测定方法多巴胺浓度的线性范围为1×10^(-7)~5×10^(-5)mol·L^(-1),检出限为3×10^(-8)mol·L^(-1)。 Dopamine hydrochloride is often used as a specific western medicine for the treatment of myocardial infarction, cerebral infarction and epilepsy. The analysis and detection technology of this substance in vivo has attracted much attention.The chemiluminescence of the hydrogen peroxide-luminol and bifunctional graphene(GO-ABEI-Hemin) systems was strongly inhibited by dopamine hydrochloride in an alkaline medium. Accordingly, a chemiluminescence analysis method for static injection of dopamine hydrochloride was established. In this paper, the effects of the amount of GO-ABEI-Hemin bifunctional luminescent material, the p H value of the reaction medium and the amount of hydrogen peroxide on the determination of dopamine by chemiluminescence were investigated. The linear range of dopamine concentration of this method was 1×10^(-7)~5×10^(-5)mol·L^(-1), and the detection limit was 3×10^(-8)mol·L^(-1).
作者 邱淑银 柳傲雪 齐艳杰 郭哲 李桂新 QIU Shu-yin;LIU Ao-xue;QI Yan-jie;GUO Zhe;LI Gui-xin(Department of Chemistry and Applied Chemistry,Changji University,Changji Xinjiang 831100,China;School of Chemistry and Chemical Engineering,Xinjiang Normal University,Urumqi Xinjang 830054,China)
出处 《当代化工》 CAS 2022年第7期1743-1747,共5页 Contemporary Chemical Industry
基金 国家自然科学基金地区基金(项目编号:21665025)。
关键词 化学发光法 盐酸多巴胺 GO-ABEI-Hemin Chemiluminescence method Dopamine hydrochloride GO-ABEI-Hemin
  • 相关文献

参考文献15

二级参考文献133

共引文献45

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部