摘要 钢筋混凝土结构检测牵涉到钢筋截面尺寸、钢筋间距、排距、保护层厚度、混凝土密实性、混凝土强度、预埋件的位置等环节。各个施工环节质量卡控是否符合相关规范及设计要求,通过结构实体检测能直观得到结果的准确性,通过钢筋混凝土结构检测检查发现一系列的质量通病。为此,针对钢筋混凝土结构检测各个节点中存在相关问题做简便的分析,通过分析总结施工过程的缺陷,针对性制订切实可行的处理措施以提高各环节的质量卡控并防止质量事故,消除隐患确保工程质量优良。 The detection of reinforced concrete structures involves the dimensions of the cross-section of the steel bars, the spacing between the steel bars, the row spacing, the thickness of the protective layer, the compactness of the concrete, the strength of the concrete, and the location of the embedded parts. Whether the quality control of each construction link meets the relevant specifications and design requirements, the accuracy of the results can be intuitively obtained through the inspection of structural entities, and a series of common quality problems have been found through the inspection and inspection of reinforced concrete structures. To this end, the main purpose is to make a simple analysis of the related problems in the detection of each node of the reinforced concrete structure. By analyzing and summarizing the defects in the construction process, we can formulate practical and feasible measures to improve the quality control of each link and prevent quality accidents., leaving no hidden dangers to ensure good project quality.
作者 李兴卫 Li Xing-wei
出处 《建筑技术开发》 2022年第15期153-156,共4页 Building Technology Development
关键词 钢筋混凝土结构 检测 问题分析与对策 reinforced concrete structure detection problem analysis and countermeasures
  • 相关文献

参考文献2

二级参考文献5

  • 1建筑施工手册编写组.建筑施工手册(第3版)[M].北京,中国建筑工业出版社,1999.
  • 2王铁梦.工程结构裂缝控制[M].中国建筑工业出版社,1998.
  • 3A.M.内维尔,混凝土的性能[M].中国建筑工业出版社,1983.
  • 4混凝土结构设计规范(GB50010一2002)[S].
  • 5李双录.现浇钢筋混凝土楼板裂缝的成因与防治[J].山西建筑,2003,29(8):74-75. 被引量:7

同被引文献24

引证文献4

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部