摘要 某电厂汽动给水泵前置泵在运行期间经常出现泵壳中分面易泄漏的问题,针对前置泵的形式和材料进行分析讨论,同时对前置泵进行相应的改造。结果表明:改造后前置泵运行情况良好,未出现泄漏现象,并且性能有所提高,可以为有同类型前置泵的电厂提供参考。 To solve the problem that the leakage occurred frequently in the middle plane of the booster pump of the steam turbine-driven feedwater pump in a power plant during operation,analyses and discussions were conducted on the structure and material of the booster pump,and corresponding measures were carried out for the booster pump.Results show that after retrofitting,the booster pump can operate in a good condition and without leakage,while the performance of the booster pump is improved.This may serve as a reference for power plants with similar booster pumps.
作者 和永涛 王兆利 He Yongtao;Wang Zhaoli(Jiangsu GuoxinYangzhou Power Generation Co.,Ltd.,Yangzhou 225131,Jiangsu Province,China)
出处 《发电设备》 2022年第5期363-366,共4页 Power Equipment
关键词 电厂 汽动给水泵 前置泵 泄漏 泵壳 power plant steam turbine-driven feedwater pump booster pump leakage pump shell