摘要 热源厂内单体复杂、火灾危险性较高。结合工程实例,从给水形式、室外消火栓系统、室内消火栓系统、消防水幕系统、室内消防炮系统、消防水箱、消防水池及泵房和消防水泵接合器几方面,对热源厂内几个重要的单体进行消防给水设计。 The heat source plant has complex monomer and high fire hazard.Combining with engineering examples,the fire water supply design is carried out for several important monoliths in the heat source plant in terms of water supply form,outdoor fire hydrant system,indoor fire hydrant system,fire curtain system,indoor fire cannon system,fire water tank,fire pool and pump room and fire pump jointer.
作者 王春妹 张伯镇 霍晓鹏 翟渺 Wang Chunmei;Zhang Bozhen;Huo Xiaopeng;Zhai Miao(Xi'an Branch,Shanghai Municipal Engineering Design and Research Institute(Group)Co.,Ltd,Xi'an Shaanxi 710000;Xi'an International Land Port Industry Development Company Limited,Xi'an Shaanxi 710000)
出处 《现代工业经济和信息化》 2022年第8期342-344,共3页 Modern Industrial Economy and Informationization
关键词 热源厂 锅炉房 消防给水设计 消防水幕系统 室内消防炮系统 heat source plant boiler room fire-feeding design fire-fighting water curtain system indoor fire-fighting cannon system