摘要
指出列车在UUS区段转为FS模式后以80 km/h进行车尾保持导致列车超速的风险。为确保安全,应根据要求对限速检查范围进行延长。对3种实际场景进行分析,并提出延长限速检查范围的具体方案。通过现场实际运用验证所提方案的有效性和可行性,为后续工程的应用提供借鉴。
The paper points out the risk of train overspeed caused by tail holding at 80 km/h after the train changes to FS mode in UUS section.In order to ensure safety,the inspection range of temporary speed restriction shall be extended as required.This paper analyzes three actual scenarios,puts forward a specific scheme to extend the inspection range of temporary speed restriction,and verifies the effectiveness and feasibility of the proposed scheme by field application,which provides a reference for the similar project application in the future.
作者
曾庆文
王建学
杨厅
Zeng Qingwen;Wang Jianxue;Yang Ting(Casco Signal Ltd.,Shanghai 200071,China)
出处
《铁路通信信号工程技术》
2022年第9期11-15,共5页
Railway Signalling & Communication Engineering
关键词
列控中心
临时限速
检查范围
train control center
temporary speed restriction
inspection range