期刊文献+

氦质谱检漏密封性在核级金属波纹管试验中的应用 被引量:1

Application of Helium Mass Spectrometry Leak Detection and Sealing to Nuclear Grade Metal Bellows Test
下载PDF
导出
摘要 利用氦质谱检漏技术,使核级金属波纹管密封性问题得到了有效解决。通过对被检件的试验和分析发现,核级金属波纹管泄漏的原因最大可能为焊缝附近存在微小焊接缺陷。这些缺陷虽然不在同一点,但可能形成气体泄漏通道,从而导致波纹管泄漏。氦质谱检漏技术的应用提高了核级金属波纹管检验合格率,解决了生产效率低的问题,应实施并推广。 Using helium mass spectrometry leak detection technology,the sealing problem of nuclear grade metal bellows has been effectively solved.Through the test and analysis of the tested parts,it is found that the most likely reason for the leakage of nuclear grade metal bellows is the existence of small welding defects near the weld.Although these defects are not at the same point,they may form a gas leakage channel,which results in the leakage of the bellows.The application of helium mass spectrometry leak detection technology improves the inspection qualification rate of nuclear grade metal bellows and solves the problem of low production efficiency,which should be implemented and popularized.
作者 王雪 于翔麟 张文良 张秀华 张大林 杨志新 高爽 Wang Xue;Yu Xianglin;Zhang Wenliang;Zhang Xiuhua;Zhang Dalin;Yang Zhixin;Gao Shuang(Shenyang Academy of Instrumentation Science Co.,Ltd.,Shenyang 110043,Liaoning,China)
出处 《工程与试验》 2022年第3期79-80,共2页 Engineering and Test
基金 沈阳市中青年科技创新人才支持计划项目,项目编号:RC210327。
关键词 金属 波纹管 密封性 影响因素 metal bellows tightness influencing factors
  • 相关文献

参考文献6

二级参考文献14

  • 1吴孝俭.电子元器件检漏的基本理论与方法.小型器件及电子元器件检漏技术研讨会论文集[C].北京:中国科学院北京科学仪器研制中心,航天总公司科技集团(机电集团),2000:43.
  • 2闫治平,黄淑英.氦质谱检漏仪操作维修学习班教材[Z].实用检漏技术概述,2000.
  • 3Zhanghe.Hood-envelope helium mass spectrometer test[S].BDT Zhangjiakou heat exchanger Ltd.Co.,ASME-PA-HT-E,Revision 2,2000.
  • 4Varian Associates,lnc.Introduction to helium mass spectrometer leak detection[M].First printing.Published by Varian Assoceates,lnc.611 Hansen Way,Palo Alto,California 94303,1980.
  • 5Gu Boqin,3Rinternational,1997年,36卷,4/5期,198页
  • 6Gu Boqin,Reproduzier barkeitund vergleich barkeit von las-sigkeitsme-βverfahren,1996年
  • 7真空设计手册编写组,真空设计手册,1986年
  • 8龙方,李春影,任丽华等.GB/T18193-2000真空技术-质谱检漏仪校准[S].北京:中国标准出版社,2000.
  • 9Varian Co.,INTRODUCTION TO MASS HELIUM SPECTROMETER LEAK DETECTION,Palo Alto,Califonia 94303,USA,1980.
  • 10LH Co.,电冰箱工业检漏手册(中译本),1989.