摘要
为了提高SF_(6)断路器在不同运行环境下对电力系统的管理效果,提出状态检修模式下SF_(6)断路器管理研究,计算状态检修模式下线路负载,以此得出电流总量,根据电压总量和电能总量对SF_(6)断路器的调节需求,利用直觉模糊将得到的调节需求转化为量化指标,作为SF_(6)断路器管理的依据,实现对电力系统参数的调节。测试结果表明,该方法可以实现不同状态检修模式下对电流的有效控制。
In order to improve the management effect of SF_(6) circuit breaker on power system under different operating environment,the management of SF_(6) circuit breakers in the condition-based maintenance mode is studied.The line load in the condition-based maintenance mode is calculated to obtain the total current.The obtained regulation requirements are converted into quantitative indicators by intuitive fuzzy,which can be used as the basis for SF_(6) circuit breaker management to realize the regulation of power system parameters.The test results show that this method can effectively control the current under different condition based maintenance modes.
作者
潘中伟
黄建波
文武甲
PAN Zhongwei;HUANG Jianbo;WEN Wujia(EHV Branch Company of State Grid Zhejiang Eiectric Power Co.,Ltd.,Hangzhou 311232,China)
出处
《电工技术》
2022年第16期99-101,共3页
Electric Engineering
关键词
状态检修模式
SF_(6)断路器
线路负载
调节需求
直觉模糊
量化指标
condition-based maintenance mode
SF_(6) circuit breaker
line load
regulation demand
intuitionistic fuzzy
quantitative index