摘要
对某110 kV油浸式变压器实际运行工况进行分析,同时对该变压器进行三维电磁仿真,获取变压器铁芯、绕组损耗及其分布。根据损耗随时间变化情况,采用一种补偿式控温方式有效调节变压器油温。
The actual operating conditions of a 110 kV oil-immersed transformer are analyzed.At the same time,the three-dimensional electromagnetic simulation of the transformer is carried out to obtain the core and winding losses and distribution of the transformer.According to the change of loss with time,a compensated temperature control method is adopted to effectively adjust the transformer oil temperature.
作者
雷剧璋
LEI Juzhang(Foshan Power Supply Bureau,Guangdong Power Grid Corporation,Foshan 528200,China)
出处
《电工技术》
2022年第16期174-176,共3页
Electric Engineering
关键词
变压器
油温
补偿式控温
损耗计算
transformer
oil temperature
compensating temperature control
loss calculation