摘要
针对轴流压气机气动性能试验中存在的低压比温升效率评估问题,构建了常规测温方法与反串测温方法测量的温升效率不确定度数学分析模型,并采用某单级压气机真实试验数据进行了两种测温方法不确定度的对比分析。结果表明:相比常规测温方法,反串测温方法不仅消除了热电偶冷端环境温度测量引入的不确定度,还大幅降低了进口温度测量引入的不确定度,使温升效率测量不确定度减小幅度在30%以上。
In view of the problem of evaluating the temperature rise efficiency under low pressure ratio in the aerodynamic performance experiments of axial flow compressor,the uncertainty mathematics analysis models of temperature rise efficiency measured by the conventional method and a method with inversed connection of thermocouple were established respectively,and the uncertainties of temperature rise efficiency measured by two methods were analyzed com-paratively with real experimental data of a single stage compressor.The results showed that,compared with conventional method,the uncertainty of temperature rise efficiency with inversed connection of thermocouple was greatly reduced by more than 30%,by eliminating the uncertainty introduced by the cold end temperature measurement of thermocouple and reducing the uncertainty introduced by the inlet temperature measurement.
作者
高杰
向宏辉
吴森林
张军
温珍荣
GAO Jie;XIANG Honghui;WU Senlin;ZHANG Jun;WEN Zhenrong(Laboratory of Turbomachinery Experiment,Sichuan Gas Turbine Establishment,Aero Engine Corporation of China,Mianyang Sichuan 621000,China;Sichuan Province Engineering Technology Research Center of Turbomachinery of Aero-engine and Gas Turbine,Mianyang Sichuan 621000,China)
出处
《航空动力学报》
EI
CAS
CSCD
北大核心
2022年第8期1732-1739,共8页
Journal of Aerospace Power
基金
民用飞机专项科研项目(MJ-2016-J-96)。
关键词
温升效率
常规测温
反串测温
热电偶
轴流压气机
temperature rise efficiency
conventional temperature measurement
temperature measurement with inversed connection of thermocouple
thermocouple
axial compressor