摘要
文章通过贺州DZZ5型国家自动气象站遭遇的1次强雷击导致设备发生故障,根据自动气象站设备结构,运用排除法分析了故障原因,并提出了正确的数据处理方法。维修过程采用的方法和流程可以为其他台站处理类似故障提供参考。
According to the equipment structure of DZZ5 national automatic weather station in Hezhou,an equipment failure caused by a strong lightning strike is analyzed by means of elimination method.The correct data processing method is proposed.The method and process used in the maintenance process can provide reference for other stations to deal with similar faults.
作者
侯江生
杨月英
Hou Jiangsheng;Yang Yueying(Hezhou Meteorological Bureau,Hezhou 542899)
出处
《气象水文海洋仪器》
2022年第3期115-116,120,共3页
Meteorological,Hydrological and Marine Instruments
关键词
国家自动气象站
雷击
故障处理
national automatic weather station
lightning strike
fault handling