摘要 提出一种针对中压三电平集成门极换向晶体管(IGCT)输出滤波拓扑下的精细化死区补偿方法,实现逆变器输出死区效应的实时计算和补偿。由输出滤波器拓扑建立传递函数,进而得到器件侧输出电流随输出电压和负载电流变化的时域解析式。将滤波器阻抗参数代入时域解析式,依据开关变化时刻的器件侧电流初值进行分段处理,计算补偿时间。该方法定量分析了含输出dv/dt滤波器拓扑应用中不同初值电流对滤波器后端电压非线性变化的影响规律,可以更加精细地补偿电流过零点处的死区效应。 A fine dead-time compensation method based on the medium voltage three-level IGCT output filtering topology was proposed to realize the real-time calculation and compensation of the dead-time effect of the inverter output.Based on the topology of the output filter,the transfer function was established,and the timedomain expression of the variation of the device side output current with the output voltage and load current was obtained.The filter impedance parameters were substituted into the time-domain analytical formula,and the compensation time was calculated by piecewise processing according to the initial value of the device side current at the time of switch change.The method take into account the influence of different initial current on the nonlinear variation of the output-end voltage of the filter in the topological application with dv/dt filter,it can compensate the dead-time effect at the zero point of the current more precisely.
作者 田凯 俞智斌 袁媛 楚子林 孙传杰 杨敬然 TIAN Kai;YU Zhibin;YUAN Yuan;CHU Zilin;SUN Chuanjie;YANG Jingran(Tianjin Research Institute of Electric Science Co.,Ltd.,Tianjin 300180,China;Operating Measurement Department National Engineering Research Center for Electric Drive,Tianjin 300180,China)
出处 《电气传动》 2022年第18期30-34,共5页 Electric Drive
基金 天津电气科学研究院有限公司科研基金(YF2021ZL006) 国机研究院青年科研基金(TD2021ZK003)。
关键词 死区补偿 三电平 集成门极换向晶体管 dv/dt滤波器 dead-time compensation three-level inverter integrated gate commutator transistor(IGCT) dv/dt filter
  • 相关文献

参考文献6

二级参考文献48

共引文献150

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部