摘要 热室是处理放射性有害物质的包容设备。热室密封门既是进出热室的主要通道,同时也是保证热室密封性能的重要组成部分。为保证热室在地震状态下的包容能力,需要对热室相关设备进行抗震计算分析。为了保证地震状态下密封门的密封性能,利用ANSYS软件构建了热室密封门的有限元模型,并进行了抗震计算。 A hot cell is a containment device for handling radioactive hazardous materials. The hot cell sealing door is not only the main channel for entering and exiting the hot cell, but also an important part to ensure the sealing performance of the hot cell. In order to ensure the containment capacity of the hot cell under earthquake conditions, it is necessary to carry out seismic calculation and analysis on the related equipment of the hot cell. In order to ensure the sealing performance of the sealing door under earthquake conditions, the finite element model of the sealing door of the hot chamber was constructed by using ANSYS software, and the seismic calculation was carried out.
作者 李阳 张弛 LI Yang;ZHANG Chi(China Nuclear Power Engineering Co.,Ltd Hebei Branch,Shijiazhuang 050019,China)
出处 《机械工程与自动化》 2022年第5期93-95,98,共4页 Mechanical Engineering & Automation
关键词 热室密封门 抗震 计算 sealed door of hot cell anti-seismic calculation