摘要
全封闭组合电器(GIS)由于自身稳定可靠的运行优势,被广泛应用到了电力系统中。不过,GIS设备对接地设置的要求较高,如果接地不良就有较大的概率导致接地故障发生。为了降低接地不良故障的发生率,将针对GIS设备特点及相关问题进行探讨。
Gas insulated metal-enclosed swit-chgear (GIS) is widely used in power system because of its stable and reliable operation advantages.However,the requirements for grounding setting of GIS equipment are high.If the grounding is poor,there is a high probability of grounding fault.In order to reduce the incidence of poor grounding fault,the characteristics of GIS equipment and related problems will be discussed.
作者
刘锋
刘秋菊
路继伟
Liu Feng;Liu Qiuju;Lu Jiwei(Henan Pingzhi high voltage switchgear Co.,Ltd.,Pingdingshan Henan,467000;School of resource development,Pingdingshan Industrial Vocational and technical college,Pingdingshan Henan,467000)
出处
《电子测试》
2022年第17期122-124,共3页
Electronic Test
关键词
全封闭组合电器
电磁感应
接地设计
Gas insulated metal-enclosed swit-chgear
Electromagnetic induction
Grounding design