期刊文献+

Optimization of design parameters for controlled rocking steel braced dual-frames

下载PDF
导出
摘要 A controlled rocking concentrically steel braced frame(CR-CSBF)is introduced as an alternative to conventional methods to prevent major structural damage during large earthquakes.It is equipped with elastic post-tensioned(PT)cables and replaceable devices or fuses to provide overturning resistance and dissipate energy,respectively.Although CR-CSBFs are not officially legalized in globally valid codes for new buildings,it is expected to be presented in them in the near future.The main goal of this study is to determine the optimal design parameters consist of the yield strength and modulus of elasticity of the fuse,the initial force of the PT cable,and the gravity load on the rocking column,considering different heights of the frame,spanning ratios and ground motion types for dual-configuration CR-CSBF.Nonlinear time-history analyses are performed in OpenSees.This study aims to define the optimal input variables as effective design parameters of CR-CSBFs by comparing four seismic responses consisting of story drift,roof displacement,roof acceleration and base shear,and also using the Euclidean metric optimization method.Despite the previous research,this study is innovative and first of its kind.The results demonstrate that the optimal design parameters are variable for various conditions.
出处 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2022年第4期1053-1068,共16页 地震工程与工程振动(英文刊)
  • 相关文献

参考文献3

二级参考文献27

  • 1Anagnos T,Comerio MC,Goulet C,Na H,Steele J,Stewart JP."Los Angeles Inventory of Nonductile Concrete Buildings for Analysis of Seismic Collapse Risk Hazards,". Proc. 14th World Conf. Earthquake Engrg . 2008
  • 2Bracci JM,Reinhorn AM,Mander JB."Seismic Retrofit of Reinforced Concrete Buildings Designed for Gravity Loads: Performance of Structural Model,". ACI Structural Journal . 1995
  • 3Christopoulos C,Filiatrault A,Folz B."Seismic Response of Self-centering Hysteretic SDOF systems,". Earthquake Engineering and Structural Dynamics . 2002
  • 4Garlock MM,Ricles JM,Sause R."Experimental Studies of Full-scale Post-tensioned Steel Connections,". Journal of Structural Engineering ASCE . 2005
  • 5Thermou GE,Elnashai AS."Seismic Retrofi t Schemes for RC Structures and Local-global Consequences,". Progress in Structural Engineering and Materials . 2006
  • 6Goel S,Lee H."Seismic Strengthening of RC Structures by Ductile Steel Bracing System,". Proc. 4th US NCEE . 1990
  • 7Harries K,Ricles J,Sause R,Pessiki S,Walkup L."Seismic Retrof it of Non-ductile Reinforced Concrete Building Columns Using FRPC Jackets,". Proc. 6th US NCEE . 1998
  • 8Kam WY,Pampanin S."Selective Weakening Techniques for Retrofit of Existing Reinforced Concrete Structures,". Proc. 14th World Conf. on Earthquake Engineering (14WCEE) . 2008
  • 9Mahin SA,Bertero VV."Nonlinear Seismic Response of a Coupled Wall System,". ASCE Journal of the Structural Division . 1976
  • 10Panian L,Steyer M,Tipping S."Post-tensioned Concrete Walls for Seismic Resistance,". PTI Journal . 2007

共引文献11