广州地铁四号线庆盛站给排水及消防设计探析

Analysis on Water Supply,Drainage and Fire Protection Design of Qingsheng Station of Guangzhou Metro Line 4
下载PDF
导出
摘要 广州地铁四号线庆盛站是全国地铁中首个在既有运营线路上不间断运营进行建设的高架站,文章对其给排水及消防设计进行介绍,分析总结给排水及消防各系统的设计情况,并重点介绍如何采用各种技术措施解决设计过程中遇到的技术难题。 Qingsheng Station of Guangzhou Metro Line 4 is the first elevated station constructed on the existing operating line which is continuously operated in China.This paper introduces its water supply,drainage and fire protection design,analyzes and summarizes the design of its water supply,drainage and fire protection systems,and focuses on how to use various technical measures to solve the technical problems encountered in the design process.
作者 李锋 Li Feng(Guangdong Zhonggong Architectural Design Institute Co.,Ltd.,Guangzhou,Guangdong 510700)
出处 《工程技术研究》 2022年第16期160-162,共3页 Engineering and Technological Research
关键词 既有运营线路 给排水系统 消防系统 污水一体化处理设备 虹吸雨水系统 existing operating lines water supply and drainage system fire protection system integrated sewage treatment equipment siphon rainwater system
  • 相关文献

参考文献7

二级参考文献22

  • 1彭东明.大型地下商业建筑消防设计探讨——深圳晶岛国际广场地下商业建筑空间及消防设计[J].工业建筑,2009,39(S1):168-170. 被引量:7
  • 2经建生,倪照鹏,马恒,等.GB50016-2006建筑设计防火规范[S].北京:中国计划出版社,2006.
  • 3中国市政工程西南设计研究院.给排水设计手册第1册[M].北京:中国建筑工业出版社,2000.
  • 4中国市政工程中南设计研究院.给排水设计手册第8册[M].北京:中国建筑工业出版社,2002.
  • 5施仲衡,周庆瑞,郑晓薇,等.GB50157-2003地铁设计规范[S].北京:中国计划出版社,2003.
  • 6孙玉林,王冠军,萧正辉,等.GB50336-2002建筑中水设计规范[S].北京:中国计划出版社,2003.
  • 7铁道第三勘察设计院.沈阳市地铁一号线工程总体设计文件[Z].天津:2004.
  • 8铁道第三勘察设计院.沈阳市地铁一号线工程初步设计文件[Z].天津:2006.
  • 9铁道第三勘察设计院.沈阳市地铁一号线工程车辆段施工图设计[Z].天津:2007.
  • 10张淼,刘振印,冯旭东,等.GB50015-2003建筑给水排水设计规范[S].北京:中国计划出版社,2009.