摘要 双馈风力发电机遭受电压故障时的瞬态特性分析特别是转子电流的分析已引起广泛关注。因此,该文对双馈感应发电机(doubly fed induction machine,DFIG)的瞬态特性尤其是转子电流进行具有一般意义的分析。为此,该文提出一种基于空间矢量的DFIG瞬态分析方法。基于此,分析双馈风力发电机遭受对称电压故障时DFIG定子磁链动态,转子开路电压动态,尤其是求出精确的转子故障电流解析式。最后,仿真验证上述方法的正确性和转子故障电流解析式的精确性。求出的DFIG转子故障电流解析式都能够精确再现DFIG遭受电压故障后的瞬态行为。 The transient characteristics analysis of DFIG-based wind turbine under voltage fault, especially the rotor current analysis, has attracted wide attention. This paper analyzed the transient characteristics of DFIG, especially the rotor current with a general significance method. Therefore, a transient analysis method based on space vector was proposed.On this basis, the stator flux dynamics and rotor open circuit voltage dynamics of DFIG under symmetrical voltage fault were analyzed, and the accurate analytical expression of rotor fault current was obtained. Finally, the correctness of the above method and the accuracy of the analytical formula of rotor fault current were verified by simulation. The analytical expressions of DFIG rotor fault current can accurately reproduce the transient behavior of DFIG after a voltage fault.
作者 凌禹 LING Yu(Department of Electrical Engineering,Shanxi Datong University,Datong 037003,Shanxi Province,China)
出处 《中国电机工程学报》 EI CSCD 北大核心 2022年第18期6871-6879,共9页 Proceedings of the CSEE
基金 大同市重点研发计划(2020015)。
关键词 风力发电 双馈感应电机 瞬态分析 转子故障电流 wind power generation doubly fed induction machine(DFIG) transient analysis rotor fault current
  • 相关文献

参考文献11

二级参考文献113

共引文献310

同被引文献40

引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部