期刊文献+

肺小磨玻璃结节胸腔镜切除术前CT引导下Hook-wire定位的应用价值 被引量:2

Application value of Hook-wire localization under CT guidance before thoracoscopic resection of small pulmonary ground-glass nodules
下载PDF
导出
摘要 目的探讨CT引导Hook-wire穿刺定位在胸腔镜下切除肺小磨玻璃结节的应用价值。方法选取肺部小结节患者136例为研究对象,均接受胸腔镜切除术。其中80例(观察组)术前采用CT引导Hook-wire穿刺定位,另外56例(对照组)采用CT常规体表定位。比较2组定位准确率、手术切除时间、住院时间、穿刺成功率、穿刺时间、穿刺深度、并发症总发生率以及引流时间。结果观察组定位准确率高于对照组,差异有统计学意义(P=0.0028)。观察组手术切除时间、术后引流时间短于对照组,差异有统计学意义(P<0.001或P<0.05)。观察组穿刺成功率为93.4%,高于对照组的72.2%,差异有统计学意义(P<0.001)。观察组穿刺深度小于对照组,差异有统计学意义(P<0.05)。观察组并发症总发生率为12.5%,低于对照组的19.6%,差异有统计学意义(P<0.001)。结论术前CT引导Hook-wire穿刺定位在胸腔镜下切除肺小磨玻璃结节病灶中安全性较高,可提高定位准确性、穿刺成功率,缩短手术切除时间、术后引流时间,减少并发症的发生,临床应用价值较好。 Objective To explore application value of CT-guided Hook-wire puncture localization in thoracoscopic resection of small pulmonary ground-glass nodules.Methods A total of 136 patients with pulmonary nodules were selected as study objects, and underwent thoracoscopic resection Among them, 80 cases(observation group) were treated with CT-guided Hook-wire puncture localization before surgery, and other 56 cases(control group) received CT routine body surface localization. The localization accuracy, surgical resection time, length of hospital stay, puncture success rate, puncture time, puncture depth, total incidence of complications and drainage time were compared between the two groups. Results The positioning accuracy of the observation group was higher than that of the control group(P=0.002 8). The operative resection time and postoperative drainage time in the observation group were significantly shorter than those in the control group(P<0.001 or P<0.05). The puncture success rate of the observation group was 93.4%, which was significantly higher than 72.2% of the control group(P<0.001). The puncture depth in the observation group was significantly lower than that in the control group(P<0.05). The total incidence of complications in the observation group was 12.5%, which was significantly lower than 19.6% in the control group(P<0.001). Conclusion Preoperative CT-guided Hook-wire puncture localization has a high safety in thoracoscopic resection of small pulmonary ground-glass nodules, which can improve positioning accuracy and puncture success rate, shorten surgical resection time and postoperative drainage time,and reduce the occurrence of complications. It has a good clinical application value.
作者 帕丽旦·尼亚孜 伊斯拉木江·吐尔逊 王姗姗 Palidan·NIYAZI;Yisilamujiang·TUERXUN;WANG Shanshan(Radiography Center,People′s Hospital of Xinjiang Uygur Autonomous Region,Urumqi,Xinjiang,830001;Department of Cardiothoracic Surgery,the Second Affiliated Hospital of Xinjiang Medical University,Urumqi,Xinjiang,830028)
出处 《实用临床医药杂志》 CAS 2022年第15期36-39,44,共5页 Journal of Clinical Medicine in Practice
关键词 CT引导Hook-wire穿刺 胸腔镜 肺小磨玻璃结节 定位准确性 CT-guided Hook-wire puncture thoracoscopy small pulmonary ground-glass nodule positioning accuracy
  • 相关文献

参考文献14

二级参考文献84

共引文献119

同被引文献20

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部