摘要
在介绍信息调谐匹配单元的结构与作用基础上,重点介绍PTX室外采集分机与TEM-M的配置,包括配置的原理、配置文件的编写、配置地址分配等,为ZPW-2000A轨道电路区间室外监测及诊断系统的现场运用维护提供一定参考。
Based on the introduction of the structure and function of information tuning and matching unit,this paper focuses on the confi guration of PTX outdoor acquisition unit and TEM-M,including the principle of confi guration,preparation of confi guration fi le,allocation of confi guration address,etc.,so as to provide some reference for the fi eld operation and maintenance of outdoor monitoring and diagnosis system of ZPW-2000A track circuit section.
出处
《铁路通信信号工程技术》
2022年第S01期60-65,共6页
Railway Signalling & Communication Engineering