摘要
反应堆功率控制系统的设计与核电厂的安全性和经济性息息相关。为提高其功率控制性能,本研究以某压水堆核电厂为研究对象,建立了其非线性动态数学模型,推导了其状态空间模型;采用线性二次型高斯(LQG)最优控制方法,设计了堆芯功率控制器;进一步基于遗传算法NSGA-Ⅱ对LQR权重系数进行了多目标优化;将本文所设计的控制器与传统PID控制器进行了典型工况的仿真对比。结果表明,与传统PID控制器相比,基于NSGA-Ⅱ方法优化的LQG控制器不但响应快速、控制精度高、稳定性好,而且具有良好的鲁棒性,能获得更优越的堆芯功率控制效果。
The design of reactor power control system is closely related to the safety and economy of nuclear power plants.To improve its power control performance,a linear quadratic gaussian(LQG)controller for core power control was designed and optimized in a pressurized water reactor nuclear power plant in this study.Firstly,a nonlinear dynamic model of the reactor core was established through mechanism modeling,which consisted of the point kinetics neutron equation,the thermal dynamics equation and the reactivity equation.The reactivity equation ignores the iodine-xenon effect and considers the reactivity introduced by the control rod,the fuel Doppler effect and the coolant average temperature reactivity feedback.The nonlinear dynamic mathematical model was then linearized based on perturbation theory,and its state space model and transfer function were derived.Secondly,the LQG optimal control method was used to design the core power controller.Since the selection of the linear quadratic regulator(LQR)weight coefficients of the controller is subjective and requires high experience of the designer,and the selection efficiency is low,the optimal weight values are not always selected,while the non-dominated ranking genetic algorithm with elite strategy(NSGA-Ⅱ)has better optimal global search capability.Therefore,in this paper,the NSGA-Ⅱalgorithm was used to optimize the weighting coefficients of LQR.the multi-objective optimization objective function of reactor power and control rod travel was established by using the time multiplied by absolute value integral of error(ITAE)evaluation index,and the multi-objective optimization of LQR weight coefficients of LQG controller was carried out based on NSGA-Ⅱalgorithm.The corresponding Pareto optimal solution set and corresponding LQG controller were obtained.In order to obtain the better reactor power control performance,the LQG controller with the weighting factor corresponding to the point with the smallest power ITAE index was used for core power control.Finally,the LQG controller designed in this paper was compared with the traditional PID controller for typical operating conditions,such as±10%FP step change of load condition and±5%FP/min linear change of load condition.The results show that both the LQG controller and the conventional PID controller can control the reactor power under the above conditions and have good control performance.However,compared with the conventional PID controller,the core power LQG controller with optimized weighting coefficients designed in this paper has significantly better control performance,with faster power control speed and smaller overshoot.
作者
金鑫
李东原
秦戈
徐教珅
唐辉
王鑫
JIN Xin;LI Dongyuan;QIN Ge;XU Jiaoshen;TANG Hui;WANG Xin(State Key Laboratory of Nuclear Power Safety Monitoring Technology and Equipment,China Nuclear Power Engineering Co.,Ltd.,Shenzhen 518172,China)
出处
《原子能科学技术》
EI
CAS
CSCD
北大核心
2022年第10期2085-2095,共11页
Atomic Energy Science and Technology