期刊文献+

某1000 MW机组汽动给水泵组调试期间异常振动分析与处理 被引量:2

Vibration Analysis and Diagnosis Disposal for 1000MW Unit Turbine Feed Pump Set during Commissioning Process
原文传递
导出
摘要 某1000 MW机组汽动给水泵组在调试期间出现了不同程度的振动问题,主要表现在给水泵汽轮机单转期间振动不稳定、汽动给水泵组在盘车工况下振动偏大及汽动给水泵组在试运期间振动突变等三个方面。通过对DCS监测系统数据分析,指出动静摩擦、靠背轮连接缺陷及传感器连接线松动是导致机组异常振动的主要原因。通过延长暖机时间、拆除靠背轮定位螺栓及紧固传感器连接线后,彻底解决了该汽动给水泵组异常振动问题。 The abnormal vibration analysis and fault diagnosis for a 1000MW unit turbine feed pump set during commissioning process is presented. Based on the vibration measured data from the DCS monitoring system, we found that friction, coupling connection defect and sensor connection line looseness were the major causes of the unit abnormal vibration. By prolonging warm-up time, removing coupling locating bolt and fastening sensor connecting wire at field,the unit vibration faults were solved successfully.
作者 卢双龙 李阳海 周淼 王广庭 许涛 LU Shuang-long;LI Yang-hai;ZHOU Miao(State Grid HuBei Electric Power Company Electric Power Test Research Institute)
出处 《电站系统工程》 2022年第5期43-45,共3页 Power System Engineering
关键词 汽动给水泵组 振动 故障诊断 turbine feed pump set vibration fault diagnosis
  • 相关文献

参考文献1

二级参考文献4

共引文献2

同被引文献18

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部