期刊文献+

OrthoPilot导航系统辅助全髋关节置换提高髋臼杯安置的安全与准确性 被引量:3

Ortho Pilot navigation system assisted total hip arthroplasty improves the accuracy and safety of acetabular cup placement
下载PDF
导出
摘要 背景:人工全髋关节置换作为治疗股骨头坏死、股骨颈骨折等疾病的经典手术方式,一直存在假体位置安放不佳、术后脱位等问题。OrthoPilot导航辅助全髋关节置换理论上可以提高假体安置的准确性及安全性,目前国内对其应用于全髋关节置换的研究较少。目的:探讨OrthoPilot导航辅助全髋关节置换的可行性以及短期临床疗效。方法:回顾性分析2019年6月至2022年4月于安徽医科大学第一附属医院关节外科接受OrthoPilot导航辅助全髋关节置换的患者23例,按照性别、年龄、体质量指数及术前Harris评分进行1∶1匹配同期行徒手全髋关节置换患者23例。对术中、术后的外展角和前倾角进行测量与统计,对手术时间、总失血量、术后引流量、平均血红蛋白丢失量及术后Harris评分进行统计。结果与结论:(1)在手术时间方面,导航组为(152.4±39.9) min,非导航组为(115.3±35.4) min,两组差异有显著性意义(P=0.02);(2)在假体位置方面,导航组术中外展角为(42.3±3.5)°、术后外展角为(42.6±5.5)°,差异无显著性意义(P=0.574);导航组术中前倾角为(18.5±3.4)°、术后前倾角为(19.3±3.9)°,差异无显著性意义(P=0.567);(3)导航组术后臼杯在髋臼安全区范围内22例,安全区外1例;非导航组术后在髋臼安全区范围内17例,安全区外6例,差异有显著性意义(χ~2=4.212,P=0.04);(4)在手术疗效方面,术后两组总失血量、引流量、平均血红蛋白丢失量、Harris评分及术后下肢深静脉血栓发生率等差异无显著性意义;(5)术后平均随访3个月,两组均无早期感染及脱位患者;(6)结果表明,OrthoPilot导航辅助全髋关节置换可以提高髋臼杯安置的准确性及安全性,其短期临床效果与徒手全髋关节置换无明显差异。 BACKGROUND: As a classic surgical method for the treatment of femoral head necrosis and femoral neck fracture, total hip arthroplasty has some problems, such as poor placement of prosthesis, postoperative dislocation and so on. Ortho Pilot navigation assisted total hip arthroplasty can theoretically improve the accuracy and safety of prosthesis placement. At present, there are few studies on its application in total hip arthroplasty in China. OBJECTIVE: To explore the feasibility and short-term clinical effect of Ortho Pilot navigation assisted total hip arthroplasty.METHODS: A retrospective analysis was performed in 23 patients who received Ortho Pilot navigation assisted total hip arthroplasty in the Department of Joint surgery of the First Affiliated Hospital of Anhui Medical University from June 2019 to April 2022. A total of 23 patients with freehand total hip arthroplasty were matched at 1:1 according to sex, age, body mass index and preoperative Harris score. The anteversion and inclination angles during and after operation were measured and counted. The operation time, total blood loss, postoperative drainage, average hemoglobin loss and postoperative Harris scores were calculated. RESULTS AND CONCLUSION:(1) The operation time in the navigation group was(152.4±39.9) minutes and in the non-navigation group was(115.3±35.4) minutes, with statistically significant(P=0.02).(2) In terms of angle measurement, the anteversion angle of acetabular cup was(42.3±3.5)° during operation and(42.6±5.5)° after operation, with no significant difference(P=0.574) in the navigation group. The inclination angle of acetabular cup was(18.5±3.4)° during operation and(19.3±3.9)° after operation, with no significant difference(P=0.567) in the navigation group.(3) According to “Lewinnek safe zone”, 22 hips were in the safety zone and 1 hip outside the safety zone after operation in the navigation group, while 17 hips were in the safety zone and 6 hips outside the safety zone after operation in the non-navigation group, showing a significant difference(χ~2=4.212, P=0.04).(4) In terms of surgical treatment, there was no significant difference in total blood loss, postoperative drainage, average hemoglobin loss, Harris score, and the incidence of postoperative lower extremity deep venous thrombosis between the two groups.(5) The average follow-up was 3 months after operation, and there were no patients with early infection or dislocation in the two groups.(6) These results verify that Ortho Pilot navigation assisted total hip arthroplasty can improve the accuracy and safety of acetabular cup placement, and its short-term clinical effect is not significantly different from that of freehand total hip arthroplasty.
作者 任毅 陆鸣 秦昆鹏 张辉 高维陆 李叶天 王俊 尹力 尹宗生 Ren Yi;Lu Ming;Qin Kunpeng;Zhang Hui;Gao Weilu;Li Yetian;Wang Jun;Yin Li;Yin Zongsheng(First Affiliated Hospital of Anhui Medical University,Hefei 230022,Anhui Province,China)
出处 《中国组织工程研究》 CAS 北大核心 2023年第27期4318-4323,共6页 Chinese Journal of Tissue Engineering Research
关键词 OrthoPilot导航 全髋关节置换术 外展角 前倾角 安全区 OrthoPilot navigation total hip arthroplasty inclination angle anteversion angle safety zone
  • 相关文献

参考文献2

二级参考文献27

  • 1Harris WH.Traumatic arthritis of the hip after disloca tion and acetabular fractures:treatment by mold arthro plasty.An end-result study using a new method of result evaluation[J].J Bone Joint Surg Am,1969,51(4):737-755.
  • 2Barrack RL,Lavernia C,Ries M,et al.Virtual reality comput-er animation of the effect of component position and design on stability after total hip arthroplasty[J].Orthop Clin North Am,2001,32(4):569-577.
  • 3Kennedy JG,Rogers WB,Soffe KE,et al.Effect of ace-tabular component orientation on recurrent dislocation,pelvic osteolysis,polyethylene wear,and component mi-gration[J].J Arthroplasty,1998,13(5):530-534.
  • 4Jolles BM,Zangger P,Leyvraz PF.Factors presdisposing to dislocation after primary total hip prosthesis[J].J Ar-throplasty,2002,17(3):282-288.
  • 5Del Schutte H,Lipman AJ,Bannar SM,et al.Effects of acetabular abduction on cup wear rates in total hip ar-throplasty[J].J Arthroplasty,1998,13(6):621-626.
  • 6Lewinnek GE,Lewis JL,Tarr R,et al.Dislocations after total hip replacement arthroplasties[J].J Bone Joint Surg Am,1978,60(2):217-220.
  • 7Ranawat CS,Maynard MJ.Modern techniques of cemen-ted total hip arthroplasty[J].Tech Orthopedics,1991,6(3):17-25.
  • 8Dorr LD,Malik A,Dastane M,et al.Combined anteversion technique for total hip arthroplasty[J].Clin Orthop Relat Res,2009,467(1):119-127.
  • 9Widmer KH,Zurfluh B.Compliant positioning of total hip components for optimal range of motion[J].Jorthop Res,2004,22(4):815-821.
  • 10Yoshimine F.The safe-zones for combined cup and neck anteversions that fulfill the essential range of motion and their optimum combination in total hip replacements[J].J Biomech,2006,39(7):1315-1323.