摘要
对某硝酸磷肥装置的蒸汽放空仪表调节阀如何实现零泄漏进行了分析与研究。从阀门选型、结构等角度分析原因,研究制定实现调节阀零泄漏方案,进行详细的调节阀选型和计算。该方案已通过生产现场实践成功验证。
This paper analyzes and studies how to realize zero leakage of steam vent instrument control valve in a nitrophosphate fertilizer plant.Analyze the cause from the angle of valve selection and structure,study and formulate the scheme to realize zero leakage of control valve,and conduct detailed selection and calculation of control valve.The scheme has been successfully verified in the production field.
作者
靳向东
Jin Xiangdong(Tianji Coal Chemical Group Co.,Ltd.,Changzhi Shanxi 047500)
出处
《山西化工》
2022年第7期118-120,共3页
Shanxi Chemical Industry
关键词
调节阀
放空
阀内件
结构改进
先导
泄漏
regulating valve
venting
trim
structural improvement
forerunner
leakage