底座自适应式压电陶瓷激振装置研究

Study on PZT Excitation Device with Self-adaptive Base Structure
下载PDF
导出
摘要 针对压电陶瓷底座激励装置中可动底座结构的实现方式和微结构的安装可靠性问题进行了研究,设计了一种由上联接块、钢球和下联接块组成的点接触式可动底座结构,以及一种带有L型支撑臂的弹性支承件,制作了基于压电陶瓷的底座激励装置,搭建了MEMS微结构动态特性测试系统,对激励装置的激振性能进行了测试实验,也对3种典型微悬臂梁的动态特性进行了测试实验。研究结果表明:所设计的激励装置能够使底座结构进行自适应调节,微结构安装区域的变形量也被大幅降低了,激励带宽可达到90 kHz,具备良好的激振性能。 The realization method of the moveable base structure and the issue of the installation reliability for microstructures were studied. A point-contacted movable base structure composed of an upper connecting block, a steel ball and a lower connecting block was designed. An elastic support with L-shaped supporting arms was also designed. The base excitation device with PZT was fabricated. The dynamic measurement system for MEMS microstructures was developed. The excitation performance of the excitation device was tested. The dynamic characteristics of three typical microcantilevers were also tested. The results show that the base structure of the designed excitation device can be adaptively adjusted, and the deformation of the installation area for microstructures is greatly reduced. The excitation bandwidth of the excitation device can reach to 90 kHz. The excitation device has a good excitation performance.
作者 佘东生 洪以平 陈亚男 田江平 SHE Dongsheng;HONG Yiping;CHEN Ya′nan;TIAN Jiangping(College of Control Science and Engineering,Bohai University,Jinzhou 121013,Liaoning,China;School of Energy and Power Engineering,Dalian University of Technology,Dalian 116023,Liaoning,China)
出处 《机械科学与技术》 CSCD 北大核心 2022年第10期1623-1628,共6页 Mechanical Science and Technology for Aerospace Engineering
基金 国家自然科学基金面上项目(52071064) 辽宁省自然科学基金项目(2019-MS-007) 辽宁省教育厅重点项目(LJKZ1009)。
关键词 激励装置 可动底座结构 动态特性测试 压电陶瓷 excitation device movable base structure dynamic characteristic measurement piezoelectric ceramics
  • 相关文献

参考文献3

二级参考文献12

  • 1WEN H K. Trends and frontiers of MEMS [J]. Sensors and Actuators A, 2007,136: 62-67.
  • 2TANAKA M. An industrial and applied review of new MEMS device features[J]. Microelectronic Engineering, 2007,84 : 1341-1344.
  • 3CHOA S H. Reliability of vacuum packaged MEMS gyroscopes [J]. Microelectronics Reliability ,2005, 45 .. 361-369.
  • 4TANNER D M. MEMS reliability: where are we now? [J]. Microelectronics Reliability, 2009,49: 937-940.
  • 5RAITERI R, GRATTAROLA M, BUTT H J, et al.. Micromechanical cantilever-based biosensors [J].Sensors and Actuators B ,2001,79 : 115-126.
  • 6MERTEN J, FIONOT E, THUNDAT, et al. Effects of temperature and pressure on microcanti lever resonance response [J]. Ultramicroscopy 2003,97(1-4):119- 126.
  • 7LIN R M,WANG W J. Structural dynamics of Microsystems--current state of research and future directions [J]. Mechanical Systems and Signal Processing, 2006,1015-1043.
  • 8PETERSEN K. Silicon as a mechanical materials[J].Proceedings of IEEE on Electron Devices. 1982,70(5) :420 457.
  • 9MCSKIMIN H J. Measurement of elastic constants at low temperature by means of ultrasonic waves data for silicon and germanium single crystals and for fused silica [J]. J. Appl. Phy. 1953, (24) :988-997.
  • 10周兆英,叶雄英,崔天宏,张联.微米纳米技术及微型机电系统[J].光学精密工程,1998,6(1):1-7. 被引量:28