在集中供暖模式下,碳纤维采暖系统的能耗主要受到设定温度和铺装功率这两方面的影响。为更好的实现供暖,就需要根据气候变化来确定居民所需室内温度,并确定铺装功率、运行时间和建筑热负荷之间的关系,进而实现精准控温并确定铺装功率。本研究以某小区为实例进行探讨,得出的结论供业内同行参考借鉴。
In central heating mode,the energy consumption of carbon fiber heating system is mainly affected by setting temperature and pavement power.In order to achieve better heating,it is necessary to determine the indoor temperature required by residents according to climate change,and coordinate the relationship among pavement power,operation time and building heat load,so as to achieve accurate temperature control and determine the pavement power.This study takes a residential area as an example to discuss some useful conclusions for peer reference.
作者
田树辉
刘超
郝晓忠
吴帅
刘佳
Tian Shuhui;Liu Chao;Hao Xiaozhong;Wu Shuai;Liu Jia(Hebei Jianyan Technology Co.,Ltd.,Shijiazhuang,050227;Hebei Jianyan Energy Saving Equipment Co.,Ltd.,Shijiazhuang,050227;Qinhuangdao Road and Bridge Construction and Development Co.,Ltd.,Qinhuangdao,066000)
出处
《建设科技》
2022年第19期50-53,共4页
Construction Science and Technology
关键词
碳纤维供暖
集中供热
温度设定
铺装功率
carbon fiber heating
central heating
temperature setting
pavement power