针对医疗建筑中变压器负载率低、照明能耗大等问题,结合项目实例,从变配电系统的合理设置、照明节能、建筑设备节能、能耗监控、谐波抑制等方面阐述医疗建筑电气节能设计的思路与方法。
In view of such issues as low transformer load rate and large lighting energy consumption in medical buildings,and according to the project examples,the electrical energy⁃saving design concepts and methods of medical buildings are described in terms of the reasonable provision of the power transformation and distribution system,lighting energy saving,building equipment energy saving,energy consumption monitoring and harmonic suppression,etc.
作者
黄楚凡
HUANG Chufan(Guangzhou Design Institute Group Co.,Ltd.,Guangzhou 510620,China)
出处
《建筑电气》
2022年第10期69-75,共7页
Building Electricity
关键词
医疗建筑
单位安装指标
负荷中心
同时系数
光源
照明控制
分项计量
谐波抑制
medical buildings
unit installation indicator
load center
simultaneous factor
light source
lighting control
sub⁃metering
harmonic suppression