摘要
针对M701F4型燃气-蒸汽联合循环机组的汽轮机在启机过程中存在高压旁路阀维持45%开度而不能正常关闭的问题,通过分析高压旁路控制逻辑和运行特性,提出了三项解决措施,从而保障了机组启动安全。
Aiming at the problem that the high-pressure bypass valve of M701F4 gas-steam combined ring unit cannot close normally while maintaining 45% opening during start-up,three solutions are put forward by analyzing the control logic and operation characteristics of the high-pressure bypass,so as to ensure the start-up safety of the unit.
作者
车国营
CHE Guo-ying(CNOOC Zhuhai Natural Gas Power Generation Co.,Ltd.,Zhuhai 519050,China)
出处
《应用能源技术》
2022年第9期1-4,共4页
Applied Energy Technology