摘要 部分小微企业用户生产方式随市场需求、季节变化较大,但该部分用户对无功补偿的重要性认识不足,用户侧欠补偿现象时有发生,在电力供应紧张的情况下将严重影响电网的供电能力和供电质量。用户每月也会因功率因数不达标,受到功率因数调整电费考核。为提高电网的供电能力和供电质量,降低用户经营成本,文章就某用户功率因数调整电费过高的案例分析用户侧无功补偿管理和调整策略。 The production mode of some small and micro enterprises varies greatly with market demand and seasons.However,they do not fully understand the importance of reactive power compensation.Undercompensation on the user side occurs occasionally.In the case of tight power supply,it will seriously affect the quality of power supply.Users will also be assessed for the power factor adjustment charge every month because the power factor does not meet the stan‐dard.In order to improve the power supply capacity and quality of the power grid,and reduce the user's operating costs,this paper analyzes the user side reactive power compensation management and adjustment strategy in the case of a us‐er's excessive power regulation charge.
作者 付雪 贾春生 李振 FU Xue;JIA Chunsheng;LI Zhen(State Grid Beijing Shunyi Power Supply Company,Beijing Shunyi 101300,China)
出处 《农村电气化》 2022年第11期87-89,共3页 Rural Electrification
关键词 无功补偿 功率因数调整 电费 reactive compensation power factor adjustment electricity fees