摘要
针对医院排水特点,总结了医院排水管道系统设计的主要功能要求、设计原则;总结了规范要求的排水管道不能进入或穿越的区域,毗邻不能有卫生间或盥洗室的区域,分析了这些区域上方不能避免有排水点时,采用同层排水或做夹层的具体处理方法;列举了有特殊排水水质的科室或功能房间,排水管道需要独立系统的情况,特殊水质的管材选用等。
According to the characteristics of hospital drainage,the main functional requirements and design principles of hospital drainage pipeline system are summarized.This paper summarizes the areas that the drainage pipeline can not enter or pass through,and the areas adjacent to which there is no bathroom or lavatory,and analyzes the specific treatment methods of using the same layer drainage or interlayer when the drainage point above these areas cannot be avoided.It lists the departments or functional rooms with special drainage quality,the situation that drainage pipes need independent system,the selection of pipes with special drainage quality,etc.
作者
黄军福
曾庆祥
Huang Jun-fu;Zeng Qing-xiang
出处
《建筑技术开发》
2022年第20期17-19,共3页
Building Technology Development
关键词
医院排水
同层排水
管道夹层
分质排水
排水管材
hospital drainage
same layer drainage
pipeline interlayer
mass drainage
drainage pipe