摘要
直流蒸汽发生器二次侧材料的腐蚀产物会沉积在传热管表面形成积垢,为明确积垢对其热工水力参数的影响,本研究基于热工水力模块化程序LOCUST,分析了不同的积垢厚度对直流式蒸汽发生器传热管壁面温度、换热系数、压降和含气率的影响程度。研究结果表明,直流蒸汽发生器二次侧积垢主要出现在汽化区域,一旦积垢产生,其换热能力下降。本研究结果为考虑积垢对直流式蒸汽发生器换热能力的影响提供了设计参考依据。
The corrosion products of materials in secondary circuit will deposit on OTSG(Once-Through Steam Generator)heat transfer tubes and form fouling.In order to clarify fouling effect on the thermal-hydraulic parameters of OTSG,the tendency of wall temperature,heat transfer coefficient,pressure drop and void fraction under different fouling thickness were analyzed via LOCUST,a modular thermal hydraulic code.Research result shows that fouling tends to deposit in vaporization regions,and once the fouling is formed,the heat transfer capability is reduced.Designing reference of OTSG heat transfer capability considering fouling effect could be obtained via this work.
作者
阮天鸣
胡艺嵩
高雅心
RUAN Tianming;HU Yisong;GAO Yaxin(China Nuclear Power Technology Research Institute,Shenzhen of Guangdong Prov.518000,China)
出处
《核科学与工程》
CAS
CSCD
北大核心
2022年第5期1009-1014,共6页
Nuclear Science and Engineering
基金
国家自然科学基金(U20B0211,针对堆芯氧化腐蚀产物材料-热工-中子行为的多物理耦合机理)
国家自然科学基金(52171085,模拟压水堆一回路冷却剂中燃料包壳管表面污垢沉积行为与机理研究)
广东省科技厅支持项目(2017B020242001,三代核电ACPR50S海上小型反应堆主设备直流蒸汽发生器关键技术研究)。