期刊文献+

荧光碳量子点对印染废水中锑离子的快速检测 被引量:1

Rapid detection of antimony ions in dyeing wastewater by fluorescent carbon quantum dots
下载PDF
导出
摘要 针对印染废水中锑的污染问题,利用Sb^(3+)与Sb^(5+)对碳量子点的荧光猝灭机制,建立了氮掺杂荧光碳量子点纳米探针对印染废水中锑离子的快速检测方法.以一步水热法合成了氮掺杂荧光碳量子点,以碳量子点荧光猝灭程度检测锑离子浓度.结果表明:锑离子检出限为3.71μg/L,线性范围为10~80μg/L,加标回收率为90.07%~111.26%,相对标准偏差为0.22%~4.88%;所提方法具有经济、快速、灵敏的优点,适合锑离子的现场快速检测. Aiming at the pollution of antimony in dyeing wastewater,by using the fluorescence quenching effect of Sb^(3+)and Sb^(5+)on carbon quantum dots,a rapid detection method of nitrogen-doped fluorescent carbon quantum dot nanoprobes for antimony ions in dyeing wastewater was established.The nitrogen-doped fluorescent carbon quantum dots were synthesized by a one-step hydrothermal method.The antimony ion concentration was detected by the fluorescent quenching degree of carbon quantum dots.The results show that the detection limit of antimony ions is 3.71μg/L,and the linear range is from 10μg/L to 80μg/L.The index recovery ranges from 90.07%to 111.26%,and the relative standard deviation(RSD)is in the range from 0.22%to 4.88%.The as-proposed method is economical,rapid,sensitive,and it is suitable for rapid on-site detection of antimony ions.
作者 张爱玲 孙泽飞 赵健 刘宁 雷永乾 ZHANG Ai-ling;SUN Ze-fei;ZHAO Jian;LIU Ning;LEI Yong-qian(School of Environmental and Chemical Engineering,Shenyang University of Technology,Shenyang 110870,China;Guangdong Institute of Analysis(China National Analytical Center Guangzhou),Guangdong Academy of Sciences,Guangzhou 510070,China)
出处 《沈阳工业大学学报》 CAS 北大核心 2022年第6期631-635,共5页 Journal of Shenyang University of Technology
基金 国家自然科学基金项目(21707128).
关键词 氮掺杂碳量子点 印染废水 锑离子 荧光纳米探针 水热法 荧光猝灭 现场检测 检出限 nitrogen-doped carbon quantum dot dyeing wastewater antimony ion fluorescent nanoprobe hydrothermal method fluorescent quenching on-site detection detection limit
  • 相关文献

参考文献1

二级参考文献18

共引文献1

同被引文献31

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部