期刊文献+

固定基准法电极定位精度研究

Research on positioning accuracy of electrode under fixed datum method
下载PDF
导出
摘要 基于精密快换夹具、精密加工中心和精密电火花机,研究采用固定基准法进行电极定位的精度,对定位精度的变化趋势和影响因素进行分析。试验结果表明:固定基准法的定位精度受到型体在电极上的坐标、型体截面尺寸、电极高度以及工件在电火花机上的安装位置等因素的影响,固定基准法具有与基准台法同等的定位精度。 Based on the precision magic chuck,precision machining center and precision EDM,the positioning accuracy of electrode using fixed datum method was studied,and the changing trend and influencing factors of the positioning accuracy were analyzed.The test results showed that the positioning accuracy of the fixed datum method was affected by the coordinate of the part on the electrode,the section size of the part,the electrode height and the installation position of the workpiece on EDM,and the fixed datum method has the same positioning accuracy as the standard station method.
作者 刘明洋 侯庆功 崔凤有 LIU Ming-yang;HOU Qing-gong;CUI Feng-you(Jiangsu Vocational College of Information Technology,Wuxi,Jiangsu 214153,China)
出处 《模具工业》 2022年第11期66-70,76,共6页 Die & Mould Industry
关键词 电极 快换夹具 定位基准 定位精度 试验研究 electrode magic chuck positioning datum positioning accuracy experimental study
  • 相关文献

参考文献5

二级参考文献10

共引文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部