期刊文献+

基于logistic回归模型的我国数字X射线摄影设备状态检测初检合格率影响因素分析 被引量:1

Logistic regression model-based analysis of influencing factors of initial testing qualified rate of condition monitoring of digital radiography devices in China
原文传递
导出
摘要 目的分析我国数字X射线摄影(DR)设备状态检测初检合格率的影响因素,为明确下一步的全国医用辐射防护监测工作重点提供科学依据。方法通过全国放射卫生信息平台—全国医用辐射防护监测系统,采集2020年全国31个省份上报的DR设备质量控制检测数据,采用logistic回归模型对DR设备状态检测初检合格率的相关影响因素进行分析。结果logistic回归分析结果显示,放射卫生技术服务机构性质、医疗卫生机构级别和地区是DR设备状态检测初检合格率的独立影响因素(χ^(2)=15.41~21.18,P<0.05)。民营机构组(OR=1.714,95%CI:1.310~2.243)、三级医院组(OR=1.710,95%CI:1.310~2.232)和二级医院组(OR=1.540,95%CI:1.203~1.971)DR设备初检合格的概率较高,西部地区组(OR=0.670,95%CI:0.526~0.852)DR设备初检合格的概率较低。结论应加强对DR设备质量控制检测的监督力度,建议加强检测设备的抽检和复核,重点关注西部地区和一级及未定级医院DR设备的质量控制检测。 Objective To analyze the influencing factors on initial testing qualified rate of condition monitoring of digital radiography(DR)devices in China and provide the scientific basis for key points of national medical radiation protection monitoring work.Methods The data of quality control detection of DR devices,reported by 31 provinces in 2020,were collected from National Radiation Health Information Platform-National Medical Radiation Protection Monitoring System.Logistic regression was used to analyze the related influencing factors of initial testing qualified rate of condition monitoring of DR devices.Results The result of logistic regression analysis showed that the nature of radiological health technical service institutions,the level of medical and health institution and the regions where they are located in China were the independent influencing factors of initial testing qualified rate of condition monitoring of DR devices(χ^(2)=15.41-21.18,P<0.05).Private institution group(OR=1.714,95%CI:1.310-2.243),tertiary hospital group(OR=1.710,95%CI:1.310-2.232)and secondary hospital group(OR=1.540,95%CI:1.203-1.971)had a higher qualified probability of DR devices,while western region group(OR=0.670,95%CI:0.526-0.852)had a lower qualified probability of DR devices.Conclusions Supervision on quality control of DR devices should be strengthened,such as strengthening the random inspection and double-check to the devices.And great attention should be paid to the quality control testing of DR devices in the western China and in the primary and ungraded hospitals.
作者 李梦雪 张子扬 邓君 徐辉 程金生 孙全富 Li Mengxue;Zhang Ziyang;Deng Jun;XuHui;Cheng Jinsheng;Sun Quanfu(Key Laboratory of Radiological Protection and Nuclear Emergency,China CDC,National Institute for Radiological Protection,Chinese Center for Disease Control and Prevention,Beijing 100088,China)
出处 《中华放射医学与防护杂志》 CAS CSCD 北大核心 2022年第10期787-792,共6页 Chinese Journal of Radiological Medicine and Protection
关键词 数字X射线摄影设备 质量控制 状态检测 LOGISTIC回归模型 Digital radiography devices Quality control Condition monitoring Logistic regression model
  • 相关文献

参考文献9

二级参考文献60

共引文献67

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部