期刊文献+

沟槽充液辐射板蓄冷特性研究 被引量:1

Study on Cold Storage Characteristics of Grooved Liquid Filled Radiant Plate
下载PDF
导出
摘要 对新型沟槽充液式辐射板供冷特性进行研究,利用冬季室外低温环境作为冷源,沟槽内部充有液体,具有较好的蓄冷性能,可在非用电高峰期间储存冷量,用电高峰时释放出来,文中对不同实验工况进行研究、分析,与普通辐射板相比,新型沟槽辐射板室内温度波动较稳定,供冷量为68.4~80.2 W/m^(2),经过后期设计,有着更大的节能潜质,也可减少室内安装面积,具有很好的经济性。 This paper studies the cooling characteristics of a new groove liquid filled radiant panel.The outdoor low-temperature environment in winter is used as the cold source.The groove is filled with liquid and has good cold storage performance.It can store the cold capacity during off-peak power consumption and release it during peak power consumption.Different experimental conditions are studied and compared with ordinary radiant panel.The indoor temperature fluctuation of the new grooved radiant panel is relatively stable,and the cooling capacity is 68.4-80.2 W/m^(2).After later design,it has greater energy-saving potential,can also reduce the indoor installation area,and has good economy.
作者 肖凱天 李曌然 邓美奇 杨绘乾 徐科文 刘冠志 XIAO Kaitian;LI Zhaoran;DENG Meiqi;YANG Huiqian;XU Kewen;LIU Guanzhi(Northeast Forestry University,Harbin 150040,China)
机构地区 东北林业大学
出处 《机械工程师》 2022年第12期77-79,共3页 Mechanical Engineer
基金 国家级大学生创新创业训练计划项目“沟槽辐射板蓄冷调峰特性研究”(202110225049)。
关键词 新型沟槽充液式辐射板 节能 时间常数 辐射供冷 new grooved liquid filled radiant plate energy saving time constant radiant cooling
  • 相关文献

参考文献6

二级参考文献34

  • 1叶宏,王军,庄双勇,葛新石,徐斌.定形相变贮能式地板辐射采暖系统的实验研究[J].太阳能学报,2004,25(5):651-656. 被引量:32
  • 2孙丽颖 马最良.冷却吊顶空调系统的设计要点[C]..暖通空调新技术(2)[C].北京:中国建筑工业出版社,2000.61-64.
  • 3B. Costelloe, D. finn. Indirect evaporative cooling potential in air - water systems in temperate climates, Energy and Building 35 (2003) 573- 519.
  • 4Atila Novoselac, Jelena Srebric. A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems, Energy and Buildings,34(2002) 497 - 509.
  • 5Claude- Alain Roulet, Jean- Pierre Rossy, Yves Roulet.Using large radiant panels for indoor climate conditioning, Energy and Buildings 30 1999 121 - 126.
  • 6J. L. Nir, L.Z. Zhang. Energy saving potential of chilled -ceiling combined with desiccant cooling in hot and humid climates, Energy and Buildings 34 (2002) 487- 495.
  • 7L. Z. Zhang. Indoors humidity behaviors associated with decoupled cooling in hot and humid climates, Building and Environment 38(2003) 99 - 107.
  • 8Franc Sodec. Economic viability of cooling ceiling systems, Energy and Buildings 30(1999)195- 201.
  • 9J.L.Nir, L.Z.Zhang. Energy saving potential of chilled -ceiling combined with desiccant cooling in hot and humid climates, Energy and Buildings 34 (2002) 487-495.
  • 10吴晓红.低温地面辐射供暖的供热调节方法研究[J].中国新技术新产品,2009(13):58-58. 被引量:2