期刊文献+

低温省煤器在火力发电厂中的优化改造研究 被引量:2

Study on Optimization and Transformation of Low Temperature Coal Province in Thermal Power Plant
下载PDF
导出
摘要 针对某电厂的1000MW燃煤机组的低温省煤器的优化设计进行探讨,从现存在的问题,出现问题的原因,优化改造原理,优化步骤,等方面进行探讨,并将优化的具体结构及参数根据实际情况进行试验,对于不同原因引起的低温省煤器出现的问题,进行解决;起到了节能降耗,保持长周期安全运行,能源利用率高的效果。 The optimization design of low temperature economizer of 1000 MW coal-fired unit of a power plant is discussed,from the existing problems,the causes of the problems,the principle of optimization,optimization steps,and other aspects are discussed,and the specific structure and parameters of optimization are tested according to the actual situation,to solve the problems caused by different reasons of low temperature economizer.It has the effect of saving energy and reducing consumption,maintaining long cycle safe operation and high energy utilization rate.
作者 姜艳则 JIANG Yanze(Shenmu Vocational&Technical College,Yulin 719300,China)
出处 《工业加热》 CAS 2022年第11期7-10,共4页 Industrial Heating
基金 陕西省教育厅2021年度专项科研计划项目(21JK0624)。
关键词 低温省煤器 实际运行 技术改造 优化设计 low and low temperature economizer actual operation technical transformation optimization design