消防水泵房供配电系统设计 被引量:1

Design of Power Supply and Distribution System for Fire Pump Room
原文传递
导出
摘要 受现有灭火技术限制,我国目前高层建筑和超高层建筑发生火灾时主要依靠建筑内部设置的灭火设施实施灭火自救,消防水池为灭火提供需要的水源,消防水源需经过消防水泵加压后才能为发生火灾场所提供足够的灭火水流量和扬程,因此,保证消防水泵内消防水泵可靠运行是扑灭火灾是否成功的关键。面对消防水泵在建筑灭火过程中的作用要求,消防水泵房供配电系统设计是否科学合理显得尤其重要。为此,本文对消防水泵房供配电系统设计关键要点及设计通病进行了详细论述。 Due to the limitations of existing fire extinguishing technologies,at present in China,when high-rise buildings and super high-rise buildings are in fire,they mainly rely on the fire extinguishing facilities set inside the buildings to carry out fire fighting and self rescue.The fire pool provides the necessary water source for fire fighting.The fire water source needs to be pressurized by the fire pump to provide sufficient fire extinguishing water flow and lift for the fire place.Therefore,to ensure the reliable operation of the fire pump in the fire pump is the key to the success of fire fighting.In the face of the function requirements of fire pumps in the process of building fire fighting,it is particularly important whether the power supply and distribution system design of fire pump room is scientific and reasonable.For this reason,this paper discusses in detail the key points and common problems in the design of the power supply and distribution system of the fire pump room.
作者 任伟 Ren Wei(Naning Xinghua Architectural Design and Research Institute Co.,Ltd)
出处 《绿色建造与智能建筑》 2022年第11期66-68,共3页 GREEN CONSTRUCTION AND INTELLIGENT BUILDING
关键词 消防水泵房 消防水泵 供配电系统 设计通病 fire water pump room fire pump power supply and distribution system common design problems