摘要
为了更好地了解巴西国家标准与NFPA标准、中国消防标准之间的差异,本文结合巴西某风电叶片厂的工程设计实例,介绍了3种标准对储存A组塑料的高堆垛材料仓库自动喷水灭火系统的设计差异,主要从系统设计参数、消防水泵和消防稳压泵3个方面进行对比,最后给出巴西工业项目自动喷水灭火系统设计建议。
In order to better understand the differences between ABNT NBR standards,NFPA standards and Chinese fire protection standards,based on the engineering design example of a wind turbine blade plant in Brazil,the design differences of 3 standards for the automatic sprinkler system of high-stack material warehouses storing Group A plastics is introduced;the system design parameters,fire pump and fire stabilized pressure pump are mainly compared,and finally the design suggestions for the automatic sprinkler system of the Brazilian industrial project are given.
作者
秦江江
王洲亚
董卫红
QIN Jiangjiang;WANG Zhouya;DONG Weihong(SINOMA Overseas Engineering Co.,Ltd.,Beijing 100073,China;Internationd Engineering branch,China Stare Construction Engineering Co.,Ltd.,Beijing 100029,China)
出处
《工程建设》
2022年第11期36-41,共6页
Engineering Construction
关键词
巴西国家标准
NFPA标准
中国消防标准
自喷系统
设计参数
差异分析
ABNT NBR standard
NFPA standard
Chinese fire protection standard
sprinkler system
design parameters
variation analysis