摘要
山东某化工厂废碱焚烧炉配套的高温电袋除尘器在投运后,电场频繁出现短路现象,导致除尘器阻力增大,通过现场调试电场参数、优化除尘器结构,有效解决了废碱焚烧炉高温电袋除尘器电场缺陷,提高了设备的运行稳定性。
After the high-temperature electrostatic bag filter matched with the waste alkali incinerator of a chemical plant in Shandong was put into operation,the electric field frequently appeared short circuit,which led to the increase of the resistance of the dust remover.Through on-site debugging of electric field parameters and optimization of the dust remover structure,the electric field defects of the high-temperature electrostatic bag filter of the waste alkali incinerator were effectively solved,and the operation stability of the equipment was improved.
关键词
电袋除尘器
积灰
电场
electrostatic bag filter
ash deposition
electric field