期刊文献+

等温变换开车试运行探讨 被引量:1

Summary of Commissioning&Test Run Featuring Isothermal CO Shift
下载PDF
导出
摘要 介绍了安徽泉盛化工有限公司等温变换装置项目概况及原始开车试运行情况,其采用湖南安淳高新技术有限公司自主研发的两级等温变换技术,等温变换装置出口CO设计值为0.4%,运行数据优于设计值,经济效益明显,开车试运行总结的经验可为其他等温变换装置运行提供参考。 This paper introduces the overview of isothermal CO shift device and the results of original commissioning&test run of Anhui Quansheng Chemical Co.,Ltd.It adopts the two-stage isothermal CO shift technology independently developed by Hunan Anchun High-tech Co.,Ltd.The design value of CO at the outlet of the isothermal CO shift device is 0.4%,which is not as good as the operation data.The corresponding economic benefits are obvious.Such summarized experience during commissioning&test run can provide useful reference for the operation of other isothermal CO shift devices.
作者 刘宏伟 罗松 张彪 方国 LIU Hong-wei;LUO Song;ZHANG Biao;FANG Guo(Anhui Quansheng Chemical Co.,Ltd.,Chuzhou Anhui 233290,China;Hunan Anchun High-tech Co.,Ltd.,Changsha Hunan 410205,China)
出处 《化肥设计》 CAS 2022年第6期34-36,共3页 Chemical Fertilizer Design
关键词 项目概况 原始开车 等温变换 project overview original commissioning isothermal CO shift