摘要
依据LS/T 6402—2017《粮油检验设备和方法标准适用性验证及结果评价的一般原则》中设备适用性验证的相关规定,从准确度、重复性和稳定性三个方面验证采用X射线荧光光谱仪测定小麦中镉含量的适用性,研究结果证明了该仪器在测定小麦中镉含量方面的适用性。
According to the relevant provisions of applicability verification in LS/T 6402—2017"Inspection of grain and oils-the general principle of standard adaptability verification and evaluation results for equipments and testing methods",the applicability of X-ray fluorescence spectrometer in the determination of cadmium content in wheat(flour)was verified from three aspects of accuracy,repeatability and stability,and the results proved the applicability of the instrument in the determination of cadmium content in wheat(flour).
作者
高敬铭
尹成华
路辉丽
秦祎芳
王莉莉
GAO Jing-ming;YIN Cheng-hua;LU Hui-li;QIN Yi-fang;WANG Li-li(Henan Center for Supervision and Inspection of Grain,Oil and Feed Product Quality,Zhengzhou 450004,China;Henan Institute of Food science Co.,Ltd,Zhengzhou 450004,China)
出处
《粮食与饲料工业》
CAS
2022年第6期57-59,63,共4页
Cereal & Feed Industry
关键词
X射线荧光光谱仪
小麦
镉
适用性
验证
X-ray fluorescence spectrometer
wheat
cadmium
applicability
verification