摘要
利用2010—2018年济南章丘站逐日08:00和20:00 L波段雷达探空数据,统计分析了济南市低空逆温变化特征,并初步分析了逆温与空气质量的关系。结果表明:(1)2010—2018年济南市低空逆温发生频率为74.4%,20:00发生频率略高于08:00,夏季发生频率最低,冬季最高;低空呈现多层逆温共存的廓线形态,多出现1~3层逆温,极少出现4~5层逆温。(2)逆温厚度平均为147.4 m,主要分布在40~290 m;逆温温差平均为2.2℃,主要分布在4.5℃以下;逆温强度平均为1.8℃/100 m,主要分布在0.4~3.0℃/100 m。(3)污染越严重,逆温层数越多,逆温层越低,逆温越厚,逆温温差越大。
Based on the on L-band radar data of Jinan Zhangqiu station at 08:00 and 20:00 every day from 2010 to 2018,the characteristics of low-level inversion in Jinan were statistically analyzed,and the relationship between temperature inversion and air quality is preliminarily analyzed.The results show that:(1)From 2010 to 2018,the frequency of low-level inversion in Jinan was 74.4%,which was slightly higher at 20:00than at 08:00,the lowest in summer and the highest in winter;The low altitude presents the contour shape of coexistence of multilayer inversion,with 1~3 layers of inversion mostly,and 4~5 layers of inversion rarely.(2)The average thickness of temperature inversion was 147.4 m,mainly distributed in 40~290 m;The average temperature difference of temperature inversion was 2.2℃,mainly below 4.5℃.The average intensity of temperature inversion was 1.8℃/100 m,mainly distributed at 0.4~3.0℃/100 m.(3)The more serious the pollution,the more inversion layers,the lower the inversion layer,the thicker the inversion,and the greater the inversion temperature difference.
作者
何鹏程
卜庆雷
李恬
HE Pengcheng(Jinan Meteorological Bureau,Jinan,Shandong 250100)
出处
《农业灾害研究》
2022年第11期55-57,60,共4页
Journal of Agricultural Catastrophology
基金
山东省气象局预报员专项“济南市低空逆温特征及其对空气质量影响分析”(SDYBY2019-06)。
关键词
逆温
逆温厚度
逆温强度
逆温温差
空气质量
Temperature inversion
Thickness of temperature inversion
Temperature difference of temperature inversion
Intensity of temperature inversion
Air quality