调研了目前主流的医疗核磁共振设备的各项电气参数要求,结合实际工程案例,分析了医疗核磁共振机房的选址、设备供电与控制、照明、接地等系统及配电线路的谐波治理,提出了医疗核磁共振机房更合理的电气设计方法。对此类工程设计具有更好的参考意义。
This paper investigated the electrical parameter requirements of the current mainstream medical nuclear magnetic resonance equipment.Combined with actual project cases,this paper analyzed the location of the medical nuclear magnetic resonance machine room,the power supply and control of equipment,lighting,grounding systems and the harmonic treatment of power distribution lines,and put forward a more reasonable electrical design method for the medical nuclear magnetic resonance machine room,which has a better reference significance for such engineering design.
作者
张亮
孔令兵
ZHANG Liang;KONG Lingbing(China Shipbuilding NDRI Engineering Co.,Ltd.,Shanghai 200090,China)
出处
《现代建筑电气》
2022年第11期40-45,共6页
Modern Architecture Electric
关键词
核磁共振成像
电气参数
电气设计
机房
magnetic resonance imaging
electrical parameters
electrical design
machine room