摘要 从理论上分析4种中低压RR供电架构具体形式和特点。从建设成本、可靠性、供电效率等方面,对比分析数据中心分布式柴油发电机中压RR架构与2N架构技术特点。针对数据中心分布式柴油发电机中压RR架构存在的电气隔离等问题提出相应的运维保障措施,并介绍一种可实现A、B两路电源电气隔离的RR架构。 Specific forms and characteristics of four MV and LV RR power supply architectures are analyzed theoretically. The technical characteristics of MV RR architecture and 2N architecture of distributed diesel generator are compared and analyzed in terms of construction cost, reliability and power supply efficiency. In this paper,the corresponding operation and maintenance guarantee measures are put forward and an RR architecture that can realize the electrical isolation of two power sources are introduced for the electrical isolation problems existing in the MV RR architecture of distributed diesel generators.
作者 黄博 贾锋泽 宋世杰 刘学超 边一超 HUANG Bo;JIA Fengze;SONG Shijie;LIU Xuechao;BIAN Yichao(TikTok Vision Co.,Ltd,Beijing 518028,China)
出处 《建筑电气》 2022年第12期49-55,共7页 Building Electricity
关键词 RR架构 2N架构 数据中心 架构分析 运维保障 建设成本 可靠性 供电效率 RR architecture 2N architecture data center architecture analysis operation and maintenance support construction cost reliability power supply efficiency