期刊文献+

超高效液相色谱-电雾式检测器同时分析牙膏中三种表面活性剂 被引量:2

Simultaneous determination of three surfactants in toothpaste by ultrahigh performance liquid chromatography-charged aerosol detector
下载PDF
导出
摘要 建立了超高效液相色谱-电雾式检测法同时检测牙膏中月桂醇硫酸酯钠、椰油酰胺丙基甜菜碱、月桂酰肌氨酸钠等3种表面活性剂的方法.牙膏样品经甲醇水溶液(1∶1)提取后,以乙腈−50 mmol·L^(−1)乙酸铵水溶液为流动相,经C18反相色谱柱分离,电雾式检测器进行定量测定.结果表明,3种表面活性剂在10—2000 mg·L^(−1)范围内,具有良好的线性关系,线性回归系数(r)均大于0.999.在3个添加水平下,样品的平均回收率为94.32%—105.15%,相对标准偏差(RSD)为0.82%—1.40%,检出限(S/N=3)为1.98—3.75 mg·L^(−1).采用该方法对市售牙膏样品进行检测,检测结果符合产品背标,检出范围在未检出—2%. An ultra performance liquid chromatography-charged aerosol detector method was developed for the determination of sodium lauryl sulfate(K12),cocamidopropyl betainem(CAPB)and sodium N-lauroyl sarcosinate(NLS)in toothpaste.The samples were extracted by methanol:water(1:1)solution.The supernatant was separated on a C18 reversed phase column,using acetonitrile-50 mmol·L^(−1) ammonium acetate water solution as mobile phase,with charged aerosol detector(CAD).Results indicated that three surfactants had good linearity in the range of 10—2000 mg·L^(−1) with their correlation coefficient(r)more than 0.999.The average recoveries at three spiked levels ranged from 94.32%to 105.15%with their relative standard deviations(RSDs)of 0.82%—1.40%.The limits of detection(S/N=3)were in the range of 1.98—3.75 mg·L^(−1).This method was applied in the determination of real toothpaste samples,the results were in the range of not detected—2%.
作者 杨立威 李晓芳 史华进 张蕾 蔡国强 YANG Liwei;LI Xiaofang;SHI Huajin;ZHANG Lei;CAI Guoqiang(NICE Zhejiang Technology Co.Ltd.,Hangzhou,310056,China;Key Laboratory of Green Cleaning Technology&Detergent of Zhejiang Province,Lishui,Zhejiang,323000;Thermo Fisher Scientific-CN Co.Ltd.,Shanghai,201206,China)
出处 《环境化学》 CAS CSCD 北大核心 2022年第12期4190-4192,共3页 Environmental Chemistry
关键词 牙膏 月桂醇硫酸酯钠 椰油酰胺丙基甜菜碱 月桂酰肌氨酸钠 超高效液相色谱 电雾式检 测器 toothpaste sodium lauryl sulfate docamidopropyl betainem sodium N-lauroyl sarcosinate UPLC CAD
  • 相关文献

参考文献5

二级参考文献68

  • 1孙志斌,张禹负,李彩云,翁蕊,杨普华,罗幼松.阴离子与非离子表面活性剂混合体系的胶束性质[J].石油勘探与开发,2004,31(3):125-128. 被引量:31
  • 2王庆利,彭健.吐温80的安全性研究进展[J].毒理学杂志,2006,20(4):262-264. 被引量:55
  • 3田强兵.分析化学中检出限和测定下限的探讨[J].化学分析计量,2007,16(3):72-73. 被引量:122
  • 4LU Jie(陆洁),WANG Xue-bin(王学斌).Effect of Tween 80 on the lipophilicity,plasma binding and biodistribution of 99mTc tetrofosmin(吐温80对99mTc替曲膦脂溶性、血浆蛋白结合及生物分布的影响).J Beijing Norm Univ ( Nat Sci),2002,38(3):386.
  • 5Khossravi M,Kao YH,Mrsny RJ,et al.Analysis methods of polysorbate 20:A new method to assess the stability of polysorbate 20 and established methods that may overlook degraded polysorbate 20.Pharm Res,2002,19(5):634.
  • 6Brito RM,Vaz WL.Determination of the critical micelle concentration of surfactants using the fluorescent probe N-phenyl-1-naphthylamine.Anal Biochem,1986,152(2):250.
  • 7Tani TH,Moore JM,Patapoff TW.Kinetic spectrophotometric determination of Tween 80.J Chromatogr A,1997,786:99.
  • 8Shazia A,Bernd T. Separation of polysorbates by liquid chromatography on a HILIC column and identification of peaks by MALDI-TOF MS.Aanl Bioanal Chem,2011,400(7):2119.
  • 9Hewitt D,Zhang T,Kao YH.Quantitation of polysorbate 20 in protein solutions using mixed-mode chromatography and evaporative light scattering detection.J Chromatogr A,2008,1215(1-2):156.
  • 10Huang M,Penn L,Bongers J,et al.Validation of a shielded-hydrophobic-phase high-performance liquid chromatography method for the determination of residual methotrexate in recombinant protein biopharmaceuticals.J Chromatogr A,1998,828:303.

共引文献27

同被引文献33

引证文献2

二级引证文献2

相关作者