建筑排水系统水封多维安全性参数试验研究

Experimental study on multi-dimensional parameters of water seal safety in building drainage system
下载PDF
导出
摘要 建筑排水系统安全事关建筑室内居住环境的舒适性与健康性。在当前主要关注水封高度的基础上,进一步试验探究了不同水封比、正/负压持续时间以及存水弯位置对自虹吸损失影响等关系到水封安全的重要参数。结果表明:相同压力下负压持续时间影响水封损失,持续60 s的水封损失大于持续5 s的水封损失;管内负压区采用大于1的水封比、正压区采用小于1的水封比有利于减少水封损失;器具排水管水封安装高度影响水封自虹吸损失,需引起关注。 The safety of building drainage system is related to the safety and comfort of the in-door environment of the building.In addition to the current concern on the parameter of water seal height,this paper further investigated the important parameters related to the water seal safety,such as the influence of different water seal ratio and the setting position of water seal on the self-siphon loss.The results showed that the water seal loss sustained for 5s under the same pressure was less than that sustained for 60s.The water sealing ratio greater than 1 in the negative pressure section and less than 1 in the positive pressure section of the pipe can reduce the water sealing loss.The installation height of drainage water seal affects the siphon loss of water seal,which should be paid more attention.
作者 赵金辉 王守荣 方玉妹 梁磊 谭德君 兰玥莹 谢西 ZHAO Jinhui;WANG Shourong;FANG Yumei;LIANG Lei;TAN Dejun;LAN Yueying;XIE Xi(College of Urban Construction,Nanjing Tech.University,Nanjing 211800,China;Jiangsu Architectural Design and Research Institute Co.,Ltd.,Nanjing 210015,China;Nanjing Changjiang City Architectural Design Co.,Ltd.,Nanjing 210002,China)
出处 《给水排水》 CSCD 北大核心 2022年第12期106-111,共6页 Water & Wastewater Engineering
基金 江苏省住建科技项目(2020JH09)。
关键词 建筑排水 水封安全 多维参数 气压波动 疫情防控 Building drainage system Safety of water seal Multi-dimensional parameters Air pressure fluctuation Epidemic prevention
  • 相关文献

参考文献4

二级参考文献13

共引文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部