摘要 传统输灰系统气耗量大,容易发生堵管,输灰管道和阀门的磨损也大。对输灰系统的改造,将中引式仓泵改为下引式仓泵,同时安装先导式输灰系统。对改造前后进行对比可知,改造节能效果明显,压缩空气节气率达到了71%,管道磨损及堵管等问题也得到了解决。 The traditional ash conveying system has large gas consumption,so the pipes are easily blocked and the ash conveying pipe and valve are severely worn.Taking Chongqing Songzao Electric Power Co.,Ltd.as an example,the ash conveying system was renovated by converting the middle-pipe cone pump into the down-pipe cone pump and installing a pilot-operated ash conveying system.The results verified the effectiveness of the renovation in energy conservation with the conservation rate of compressed air reaching 71%.Meanwhile,such problems as the wear,blockage,etc.of the pipes were solved.
作者 焦明飞 龙海川 张竣堯 游利国 JIAO Mingfei;LONG Haichuan;ZHANG Junyao;YOU Liguo(Chongqing Songzao Electric Power Co.,Ltd.,Chongqing 401443,P.R.China;Shandong University of Science and Technology,Qingdao Shandong 266590,P.R.China)
出处 《重庆电力高等专科学校学报》 2022年第5期23-27,共5页 Journal of Chongqing Electric Power College
关键词 气力输灰 先导式 节能 流化 中引式仓泵 pneumatic ash conveying pilot-operated energy conservation fluidifying middle-pipe cone pump