摘要
论述了机楼如何采取细化分项能耗计量的颗粒度,定位高能耗的机房,根据机楼制冷系统回风温度与机房环境温度数据对比分析,实现制冷系统能效的优化提升,达到了降低机楼综合能耗的目标。
This paper discusses how to refine the granularity of energy consumption measurement,locate the equipment room with high energy consumption,analyze the return temperature of the aircraft building cooling system and the ambient temperature data of the equipment room,realize the energy efficiency of the refrigeration system,and achieve the goal of reducing the comprehensive energy consumption of the aircraft building.
作者
陈大裕
高小婷
卢运运
王龙
姚超
CHEN Dayu;GAO Xiaoting;LU Yunyun;WANG Long;YAO Chao(Network Operation Center of Wuzhou Branch of China Mobile Communications Group Guangxi Co.,Ltd.,Wuzhou 543002,China;Engineering Construction Department of Wuzhou Branch of China Mobile Communications Group Guangxi Co.,Ltd.,Wuzhou 543002,China)
出处
《通信电源技术》
2022年第20期142-144,共3页
Telecom Power Technology
关键词
分项能耗计量
颗粒度
回风温度
环境温度
itemized energy measurement
particle ularity
return temperature
ambient temperature