摘要 本文介绍了某炼化企业固定污染源烟气SO_(2)连续监测仪表的选型和应用情况,重点分析不同测量原理的SO_(2)连续监测仪在实际应用中的受干扰情况。为同类事件的原因分析和调查提供思路,并指导同类环境下的SO_(2)在线监测仪表选用,避免造成不良影响及不必要的损失。 This paper introduces the selection and application of SO_(2)continuous monitoring instrument for flue gas from a fixed pollution source in a refinery enterprise,and focuses on the analysis of the interference of SO_(2)continuous monitoring instrument with different measurement principles in practical application.It provides ideas for the cause analysis and investigation of similar events,and guides the selection of SO_(2)online monitoring instruments in similar environments to avoid adverse effects and unnecessary losses.
作者 王燎原 蔡天洲 崔小华 钟国财 朱社强 Wang Liaoyuan(PetroChina Sichuan Petrochemical Co.,Ltd.,Chengdu 611930)
出处 《化工设计》 CAS 2022年第6期42-45,2,共5页 Chemical Engineering Design
关键词 SO_(2) 烟气排放连续监测系统 甲烷 选型 干扰 SO_(2) flue gas emission continuous monitoring system methane selection interference