电感耦合等离子体原子发射光谱法测定二氧化硒中砷量的不确定度评定

Evaluation of uncertainty in the determination of arsenic in selenium dioxide by inductively coupled plasma atomic emission spectrometry
下载PDF
导出
摘要 介绍了电感耦合等离子体原子发射光谱仪测定二氧化硒中砷,依据JJF1059-1999的要求,系统的分析了检测过程中各不确定度引入的来源,计算出各种不确定度分量并将其合成,从而得出了用此方法测定二氧化硒中砷量的合成标准不确定度和扩展不确定度。 This paper introduces the determination of arsenic in selenium dioxide by inductively coupled plasma atomic emission spectrometer. According to the requirements of JJF1059-1999, the sources of each uncertainty introduced in the detection process are systematically analyzed, and various uncertainty components are calculated and synthesized, thus obtaining the synthesis standard uncertainty and expanded uncertainty for the determination of arsenic in selenium dioxide by this method.
作者 程钱夏 CHENG Qian-xia(Guixi Smelter,Jiangxi Copper Corporation,Guixi 335424,Jiangxi,China)
出处 《世界有色金属》 2022年第20期184-186,共3页 World Nonferrous Metals
关键词 电感耦合等离子体 不确定度 二氧化硒 评定 inductively coupled plasma Arsenic Uncertainty Selenium dioxide evaluate